BAC-10000 Series 1 Operation Guide, Rev. J
Operation Guide
BAC-10000 Series
FlexStat
BACnet Programmable Thermostats
Contents
Overview ................................................................2
Applications and Installation
...................................2
Operation (Basic)
....................................................3
Home, Main Menu, and Override Screens
..........3
Navigation
..........................................................3
Main Menu and Settings
...................................... 3
Room Temp. Setpoint Adjustment
.......................3
H/C, Fan, Occupancy, and Override
...................3
Configuration (Initial Setup)
...................................4
Main Menu Overview
.........................................4
About the FlexStat
...............................................4
Advanced Menu
.................................................. 5
(Advanced) Application Options
......................5
(Advanced) CB (Control Basic) Programs
.........6
(Advanced) BACnet Communications
..............7
(Advanced) Date/Time
.....................................7
(Advanced) BACnet Device Properties
.............8
(Advanced) Inputs
............................................8
(Advanced) Temp. Setpoint Limits
....................8
(Advanced) Motion Sensor
...............................8
(Advanced) Security Levels and Passwords
....... 9
(Advanced) Trend Logs
...................................10
(Advanced) Test
.............................................. 10
Alarms
............................................................... 11
Date/Time
.........................................................11
Schedules
..........................................................12
Setpoints
........................................................... 13
System Setup
.....................................................13
Trend Viewer
..................................................... 13
Resetting the FlexStat
............................................14
Types of Reset
....................................................14
Warm and Cold Starts
.......................................14
Restore Factory
.................................................15
Network Connection
............................................. 16
BACnet MS/TP Network Communication
...... 16
PC Data Port Connection
............................... 16
Troubleshooting ....................................................17
Alarm Issues
......................................................17
Alarm, (False) Fan Fail
....................................17
Alarm, (False) Low Limit (Freeze Stat)
............17
Alarm, (False) Space Temp. or Humidity
........17
Communication Issues
...................................... 17
Firmware Upgrade Fails
.................................17
KMD-5576 Communication Faulty
................17
MS/TP Network Communication Faulty
......... 17
Cover and Display Issues
...................................18
Cover Binds on Backplate
..............................18
Display Is Blank or Erratic
..............................18
Display Freezes (Buttons Have No Effect)
......18
Custom Programming and Web Issues
............... 18
Control Basic Programs Do Not Work
............18
Custom Web Graphics Do Not Work
.............18
Input, Sensor, and Value Issues
..........................19
Input Values Are Outside the Expected Range
19
Motion/Occupancy Sensor Does Not Work
... 19
Temperature Reading Is Incorrect
..................19
Temperature Setpoint Is Not Maintained
.......19
Output, Fan, and Relay Issues
...........................20
Analog Output Does Not Work
......................20
Fan Does Not Run
.......................................... 20
Relay (Internal) Does Not Work
.....................20
Relay (External) Does Not Work
....................21
Wiring Issues
.....................................................21
Maintenance
.........................................................22
Firmware Upgrade
................................................22
Programming (Custom)
.........................................22
Accessories
...........................................................22
Support
.................................................................23
Important Notices
.................................................23
Reference
..............................................................24
Acronyms and Abbreviations
.............................24
Definitions of Terms
..........................................25
Index
.....................................................................26
Specifications, design, and operation are subject to change without notice.
Vista de pagina 0
1 2 3 4 5 6 ... 27 28

Indice de contenidos

Pagina 1 - Operation Guide

BAC-10000 Series 1 Operation Guide, Rev. JOperation GuideBAC-10000 SeriesFlexStat™ BACnet Programmable ThermostatsContentsOverview ...

Pagina 2 - Applications and Installation

BAC-10000 Series 10 Operation Guide, Rev. J(Advanced) Test TESTLCD/KEY TESTThe test menu merely tests the display’s pixels and key functions.1. Up

Pagina 3 - Operation (Basic)

BAC-10000 Series 11 Operation Guide, Rev. JDate/Time DATE/TIMEDATE:TIME: 1:43:59 PMAPR 11 2009To enter date and time information (only), press:1.

Pagina 4 - Configuration (Initial Setup)

BAC-10000 Series 12 Operation Guide, Rev. J HOLIDAYSHOL1:HOL2: MAR 21 2009HOL3: MAY 26 2009HOL4: JULY 4 2009HOL5: SEPT 1 2009HOL6: NOV 27 2009HOL7:

Pagina 5 - Advanced Menu

BAC-10000 Series 13 Operation Guide, Rev. JSystem Setup SYSTEMSYSTEM ENABLE:OCC OVRIDE (HRS): 1.0INACTIVITY (SECS): 60DISPLAY BLANKING: NOAUTOTo ad

Pagina 6

BAC-10000 Series 14 Operation Guide, Rev. JResetting the FlexStatTypes of ResetIf the FlexStat is not operating correctly or if a low limit alarm ha

Pagina 7 - (Advanced) Date/Time

BAC-10000 Series 15 Operation Guide, Rev. JRestore FactoryRestore Factory (restoring the FlexStat to the factory seings) does the following:• Clea

Pagina 8 - (Advanced) Inputs

BAC-10000 Series 16 Operation Guide, Rev. JBACnet MS/TP Network CommunicationConnect the network wiring and set the EOL switch-es accordingly. (See

Pagina 9

BAC-10000 Series 17 Operation Guide, Rev. JTroubleshootingAlarm IssuesAlarm, (False) Fan Fail• Check conguration. Be sure the Fan Status option is

Pagina 10 - (Advanced) Trend Logs

BAC-10000 Series 18 Operation Guide, Rev. JCover and Display IssuesCover Binds on Backplate• Carefully remove the FlexStat cover from the backplate

Pagina 11 - Date/Time

BAC-10000 Series 19 Operation Guide, Rev. JInput, Sensor, and Value IssuesInput Values Are Outside the Expected Range• Check that ALL the input pul

Pagina 12 - Schedules

BAC-10000 Series 2 Operation Guide, Rev. JOverviewThe KMC FlexStat series of intelligent temperature/humidity/occupancy-sensing, wall-mounted, ther-

Pagina 13 - Setpoints

BAC-10000 Series 20 Operation Guide, Rev. JFan Does Not RunNOTE: The animated fan icon is coupled with BV18 in the packaged programming (not the ac

Pagina 14 - CAUTION

BAC-10000 Series 21 Operation Guide, Rev. J +B –AIN4IN3GNDIN2Common/–/CPhase/ /R Analog 9GND 7–9 Analog 8 Analog 7 Relay 6SC 4–6 Relay 5 Relay

Pagina 15

BAC-10000 Series 22 Operation Guide, Rev. JFirmware UpgradeThe existing version of rmware can be viewed from the About the FlexStat screen. (See Ab

Pagina 16 - KMD-5576

BAC-10000 Series 23 Operation Guide, Rev. JImportant NoticesThe KMC logo and TotalControl are registered trademarks and BACstage is a trademark of K

Pagina 17 - Troubleshooting

BAC-10000 Series 24 Operation Guide, Rev. JReferenceCommon acronyms and abbreviations in FlexStat and related documents include:amp = amperesA = amp

Pagina 18 - Cover and Display Issues

BAC-10000 Series 25 Operation Guide, Rev. JFor denitions of various terms in this document, refer to the award-winning pocket-sized Green Building

Pagina 19

BAC-10000 Series 26 Operation Guide, Rev. JIndexSymbols4 x 4 Handy Box Mounting Plate: 22AAbbreviations: 24About the FlexStat: 4Access Levels, Pa

Pagina 20

BAC-10000 Series 27 Operation Guide, Rev. JGGlossary, Green Buildings Controls: 25HHeat, Cool, Auto, Off (System Enable): 13HMO-10000 Mounting Pla

Pagina 21 - Wiring Issues

BAC-10000 Series 28 Operation Guide, Rev. J© 2010 KMC Controls, Inc. 913-019-02JKMC Controls, Inc.19476 Industrial Drive, New Paris, IN 46553574.8

Pagina 22 - Accessories

BAC-10000 Series 3 Operation Guide, Rev. J WED 11/19 3:20 PM COOL: OCC: FAN: H

Pagina 23 - Important Notices

BAC-10000 Series 4 Operation Guide, Rev. JConfiguration (Initial Setup)NOTE: Menus shown in this document reect rmware version R1.3.0.4 or later.

Pagina 24 - Reference

BAC-10000 Series 5 Operation Guide, Rev. JAdvanced Menu ADVANCEDAPPLICATIONCB PROGRAMSCOMMUNICATIONDATE/TIMEDEVICEINPUTSLIMITSThe Advanced Menu dis

Pagina 25 - Definitions of Terms

BAC-10000 Series 6 Operation Guide, Rev. JSensor Setup SENSOR SETUPIN 2:DISCH AIR TEMPThe Input 2 sensor (AI2) can be congured for discharge air t

Pagina 26 - See Firmware

BAC-10000 Series 7 Operation Guide, Rev. J(Advanced) BACnet Communications COMMUNICATIONSMAC ADDRESS:BAUD RATE: 38400MAX MASTER: 1271To set paramet

Pagina 27 - See EIA-485

BAC-10000 Series 8 Operation Guide, Rev. J(Advanced) Temp. Setpoint Limits LIMITSOCC MIN CLG: OCC MAX HTG: 76° FUNOCC MIN CLG: 77° FUNOCC MAX HTG:

Pagina 28 - 574.831.5250

BAC-10000 Series 9 Operation Guide, Rev. J(Advanced) Security Levels and Passwords SECURITYACCESS LEVELSPASSWORDS ACCESS LEVELSSETPOINT ADJ:MAIN M

Comentarios a estos manuales